A small peptide with a readability problem
KPV is a peptide of three amino acids: lysine, proline and valine. It is the end fragment of a hormone called alpha-MSH. The published research is mostly preclinical. It is sold for laboratory research and is not an approved medicine.
The amounts in research protocols are a few hundred micrograms, and a vial often holds 10 mg. With 2 mL of water, 250 mcg is 5 units and 100 mcg is 2 units. Marks that small are at the limit of what a 1 mL syringe can show. The calculator displays one decimal place and warns you below 2 units, so that you can see when more water, or a smaller syringe with finer marks, gives a result that is easier to read.
KPV units chart: 5, 10 and 20 mg vials
Syringe units for 3 vial sizes, each mixed with 2 mL of water.
| Vial | Water added | Concentration | Amount | Units (U-100) |
|---|---|---|---|---|
| 5 mg | 2 mL | 2.5 mg/mL | 100 mcg | 4 |
| 5 mg | 2 mL | 2.5 mg/mL | 250 mcg | 10 |
| 5 mg | 2 mL | 2.5 mg/mL | 500 mcg | 20 |
| 10 mg | 2 mL | 5 mg/mL | 100 mcg | 2 |
| 10 mg | 2 mL | 5 mg/mL | 250 mcg | 5 |
| 10 mg | 2 mL | 5 mg/mL | 500 mcg | 10 |
| 20 mg | 2 mL | 10 mg/mL | 100 mcg | 1 |
| 20 mg | 2 mL | 10 mg/mL | 250 mcg | 2.5 |
| 20 mg | 2 mL | 10 mg/mL | 500 mcg | 5 |
These rows are arithmetic examples for common vial sizes. They are not dose recommendations.
More water, more units: a 10 mg vial
For small amounts, a larger water volume spreads the same quantity over more units.
| Water added to a 10 mg vial | Concentration | Units for 250 mcg |
|---|---|---|
| 1 mL | 10 mg/mL | 2.5 |
| 2 mL | 5 mg/mL | 5 |
| 3 mL | 3.33 mg/mL | 7.5 |
Where the result comes from
The calculator applies three operations.
- Concentration = vial amount (mg) ÷ water (mL). Example: 10 ÷ 2 = 5 mg/mL.
- Volume = amount (mg) ÷ concentration. Example: 0.25 ÷ 5 = 0.05 mL.
- Units = volume (mL) × 100, for a U-100 insulin syringe. Example: 5 units.
The full method, with the rounding rules, is on the methodology page.
Syringe size and the smallest mark
All U-100 insulin syringes use the same scale: 100 units for 1 mL. The difference is the capacity and the distance between marks.
| Syringe | Capacity | Typical mark |
|---|---|---|
| 1 mL | 100 units | every 2 units |
| 0.5 mL | 50 units | every 1 unit |
| 0.3 mL | 30 units | every 1 unit or every half unit |
The number of units for an amount is the same on each of them. Check the scale printed on your own syringe.